MP stress campaign with coverage, all six boards (night 2026-11-17/18)

13 hours per board, rb-mp-stress at commit 515fc3e, one library per reset, 1,000,000 values per library and run. Prescaler 1-4 in rotation; at prescaler 3 and 4 half the runs use aimed interrupts and every run records where its interrupts landed (method: 2026-11-17-mp-coverage-prototype.md). The first campaign of this kind, and the last long one before version 1 (DECISIONS 2026-11-18).

Result

No errors in any library in its documented mode, in any run on any board. A run is valid when the control (an SPSC buffer used by two producers or two consumers) was caught in it.

Board Runs Valid Control caught, random interrupts Control caught, aimed
nRF5340 DK 64 53 37 of 48 16 of 16
NUCLEO-G0B1RE 116 105 77 of 88 28 of 28
NUCLEO-G474RE 218 206 152 of 164 54 of 54
NUCLEO-H723ZG 143 143 107 of 107 36 of 36
SAM D20 Xplained Pro 74 66 48 of 56 18 of 18
Pico 2 235 177 119 of 177 58 of 58
All 850 750 540 of 640 210 of 210

No run failed (probe, serial port or build). Every run where the control was not caught had random interrupts at prescaler 2, 3 or 4. On the Pico 2 no random run at prescaler 3 or 4 caught it (0 of 58); at prescaler 1 and 2 all 119 did.

Coverage (prescaler 3 and 4, valid runs, the control left out)

Per library and mode: the share of interrupts that landed in the library's code, the median number of interrupts per instruction boundary where one can land, and how many of those boundaries were interrupted at least 10 times in the weakest run. Range over the libraries:

Board Interrupts In library code Median per boundary Boundaries >= 10x, weakest run Rows with every boundary >= 10x
nRF5340 DK random 2.0-8.7 % 8-3,014 47-88 % 0 of 13
aimed 8.7-32.3 % 2,880-9,790 63-100 % 1 of 13
NUCLEO-G0B1RE random 6.2-14.5 % 33-2,744 55-89 % 0 of 11
aimed 14.3-42.9 % 704-15,730 84-100 % 8 of 11
NUCLEO-G474RE random 2.3-11.1 % 83-3,383 40-80 % 0 of 13
aimed 4.2-27.8 % 2,188-18,481 68-100 % 4 of 13
NUCLEO-H723ZG random 8.8-20.0 % 8-518 42-75 % 0 of 13
aimed 9.0-26.1 % 52-5,590 50-100 % 1 of 13
SAM D20 Xplained Pro random 9.1-21.0 % 96-6,530 50-91 % 0 of 11
aimed 18.2-53.6 % 433-12,289 85-100 % 8 of 11
Pico 2 random no valid run
aimed 1.9-24.5 % 1,712-7,970 61-100 % 2 of 13

Per-library tables: report.md in each campaign directory (~/lab-runs/mp-campaign-20261117T1736*Z/ on lib-lab1), boundary lists in coverage.txt.

Reading

For the publication re-run

No change is made here. A proposal for the owner, since it changes what a campaign covers: at prescaler 3 and 4 run aimed interrupts only (random runs there are often invalid and never on the Pico 2), and keep random interrupts at prescaler 1 and 2, where the control is caught reliably.